New IEEE Standard - Superseded. Direction for the design and installation of safety-related electrical cable systems, including associated circuits, in nuclear power generating stations is provided. Existing standards are identified and guidance is provided for the design and installation of those non-safety-related cable systems that may affect the function of safety-related systems. Solutions are recommended for areas of concern such as fire protection, raceways, separation, cable performance requirements, and installation acceptance testing and documentation.

Julkaisun tiedot

  • Standardi julkaisijalta IEEE
  • Julkaistu:
  • Julkaisutyyppi: IS
  • products.specs.pages
  • Publisher IEEE
  • Distributor IEEE
  • ICS 29.060.20
  • Tekninen komitea IEEE Power and Energy Society / Nuclear Power Engineering

Sidokset

  • On korvattu: IEEE 690-2004
  • Enums.Sd.Shared.Models.ProductRelationType.REFERRED_BY: IEEE 1143-1994
  • Enums.Sd.Shared.Models.ProductRelationType.REFERRED_BY: IEEE 384-1992
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: IEEE 384-1981
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: IEEE 634-1978
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: IEEE 383-1974
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: NFPA 14-1983, Standard for the Installation of Standpipes and Hose Systems.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/ASME NQA 1-1979, Quality Assurance Program Requirements for Nuclear Power Plants.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/NFPA 10-1981, Standard for Portable Fire Extinguishers.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/NFPA 15-1982, Standard for Water Spray Fixed Systems for Fire Protection.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/NFPA 90A-1981, Standard for the Installation of Air Conditioning and Ventilating Systems.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/NFPA 70-1984, National Electrical Code.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ASTM E119-1983, Standard Methods of Fire Tests of Building Construction and Materials.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: NFPA 13-1983, Standard for Installation of Sprinkler Systems.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/NFPA 72E-1982, Selection and Placement of Fire Detectors.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/NFPA 72D-1979, Installation, Maintenance, and Use of Proprietary Signaling Systems.
  • Enums.Sd.Shared.Models.ProductRelationType.REFERS: ANSI/ANS 59.4-1979, Generic Requirements for Light Water Nuclear Power Plant Fire Protection.1